Note: Use industrial touch screen with resistance
Main technical data
1. Dimension: 435¡Á293¡Á140mm
2. Input voltage: 200V¡«240V AC or 100V¡«120V AC
3. Power: ¡Ü3W
4. Accuracy of temperature measuring: ¡À1¡æ
5. Range of temperature measuring: PT1000 : 0¡«199¡æ NTC10K: 0¡«99¡æ
6. Input signals:
2 x PT1000 sensor temperature probe ¡Ü500¡æ, silicon cable ¡Ü280¡æ;
4 x NTC10K sensor temperature probe¡Ü135¡æ, PVC cable ¡Ü105¡æ
7. Output signals:
1 x Auxiliary heating output (Max. load current: 12A)
4 x Relay output (Max. load current: 1.5A)
8. System design pressure: 1 MPa
9. Safety valve respond pressure: 0.6 MPa
10. WILO pump model: RS15/6
11.Screw coupling: 3/4¨•
12.Pipeline material: Brass
13. Range of environment temperature: -10¡«50¡æ
14. Water protection grade: IP40
Main functions
1. 72 solar hot water systems for choice
2. Time display
3. Temperature difference circulation
4. Tank overheating protection
5. High temperature protection of system overheating
6. Frost protection of pipeline and collector
7. Three periods of time adjustable on pipeline circulation
8. Three periods of time adjustable on auxiliary heating
9. Holiday function
10. Anti-bacteria function
11. Three speed levels on circulation pump
12. Display flow rate
13. Display system pressure